DOAS System for High-Sensitivity Multi-Gas Monitoring and Accurate Industrial & Environmental Analysis – GAOTek
$44.62
$66.93
Description Overview Differential Optical Absorption Spectroscopy (DOAS) is a versatile broadband technique for continuous multi-gas monitoring. By measuring differential absorption across wide wavelength ranges, it detects gases from ppbv levels to very high concentrations. DOAS corrects for spectral overlap and interference, enabling accurate and reliable analysis of pollutants such as NO, SO₂, NH₃, and HCHO in industrial and environmental applications. Features High Measurement Accuracy The minimum detection limit of SO2, NO, NO2 can be 1mg/m3 (15 m optical path) Ultraviolet has no moisture absorption: undisturbed by moisture and dust. No cross interference between the gas being measured NO and NO2 can be measured at the same time, dispense with converter. Low detection limit. High Reliability DOAS PLS technology, small amount of zero drift and span drift Modular design Available version with external UV bench for use with toxic or corrosive gases. No optical moving parts and no vibration influence. Strong gas cell, low cost. Spectrum automatic adjustment technology, long free maintenance cycle Light source adopts the pulse source European Compliance Low Voltage Directive 2014/35/EU EMC Directive 2014/30/EU Measurable Gases Nitric Oxide [NO], Oxygen [O2], Chlorine [Cl2], Nitrogen Dioxide [NO2], Carbon Monoxide [CO], Hydrogen Sulphide [H2S], Sulfur Dioxide [SO2], Ammonia [NH3], Methane [CH4]. Technical Specifications Parameters Details Measuring Principle UV DOAS PLS (all the gas); Electrochemical (O2); Laser (CO) Linearity ≤ ±1.5% FS Repeatability ≤ ±0.5% FS Zero & Span Drift ≤ ±2% FS Response time (T90) < 10 sec. | < 30 sec. | < 30 sec. Working Temperature -10°C to 40°C Warmup Time No pre-heating | Approx. 10 min. Sample Gas Interface Ø6 Bi-lok Atmospheric pressure effect ± 0.13% of reading per mmHg. Sample Gas Flow 0.5…2 l/min., Fluctuation < 25% Sample Gas Pressure The current environmental pressure ±0.1 Bar Sample Temperature 0°C to 50°C Sample Gas Humidity Non condensation (under sample temperature) 4-20 mA Input Interface 3 x configurable, max. load 100 Ω 4-20 mA Output Interface 5 x configurable, max. load < 800 Ω Switch Input Interface 6 x configurable Relay Output Interface 14 x configurable, 30 VDC, 2A Communication Interface 1 x RS232, 1x RS 485 (ModBus) Installation Rack 19″ Supply 100…240 VAC Power ~ 100W | ~ 200W Outline Dimensions 132(H) x 483(W) x 378(D) mm | 177(H) x 483(W) x 412(D) mm | 177(H) x 483(W) x 412(D) mm Weight ~ 10 Kg. | ~ 12 Kg.
Gas Analyzers